For cultivation of mammalian cells in biopharmaceutical research and manufacturing, single-use technology possesses several advantages to autoclavable material. Bioreactor scalability is critical to streamlining the adaptation of culture volumes during process development and manufacturing. We analyzed BioBLU Single-Use Vessels of different sizes (maximum working volumes of 0.25 L, 3.75 L, and 40 L) that are of geometrically similar stirred-tank design. We identified a scalable tip speed zone and an overlapping range of kLa values, which cover most mammalian cell culture needs. Using computational fluid dynamics simulations we determined the power numbers of the BioBLU bioreactors. Based on these data we scaled up a process for production of monoclonal antibodies (mAb) in CHO cells from 0.25 L to 3.75 L to 40 L by keeping constant P/V values (impeller power consumption per liquid volume) among the differently sized vessels. Similar cell growth curves and mAb production profiles were achieved at all three scales. In summary, this study demonstrates the excellent scalability of the single-use bioreactors tested.